Home » Shop » 6m x 10m x 4m High – Heated Spray Room

6m x 10m x 4m High – Heated Spray Room

£59,013.00 (excl. VAT)

The 6m x 10m x 4m Heated Spray Room is a large spray and drying room designed for professional and industrial finishing applications. The insulated room incorporates a gas-fired heating system with dedicated spray and bake cycles, high-capacity rear extraction and filtered air input, providing a controlled environment for spraying and accelerated heated drying.

Key specification

  • Internal size: 6m W x 10m L x 4m H
  • Construction: Insulated steel panels
  • Finish: White Exterior / White Interior
  • Heating: Gas-fired heating system
  • Controls: Spray and bake cycle functions (Ambient up to 25°C spray mode & up to 60°C bake mode)
  • Extraction: 2 x 710mm / 4kW axial fans
  • Airflow: 23,115m³/hr per fan – 46,230m³/hr total
  • Extraction filtration: Andreae AF923 High Efficiency Filters
  • Air input: BS290 blue & white roll filter
  • Main access: 5m W x 4m H insulated white roller shutter
  • Personnel access: 2 personnel doors
  • Lighting: Internal lighting throughout
  • Ductwork: Included for standard installations up to 6m building roof height
  • Delivery & installation: UK mainland included, subject to suitable site conditions

FREE UK MAINLAND DELIVERY • INSTALLATION INCLUDED

Description

6m Wide x 10m Long x 4m High – Heated Spray Room

The 6m x 10m x 4m Heated Spray Room is a large commercial spray and drying room designed for professional and industrial applications where larger components, assemblies, vehicles and other products require a dedicated controlled environment for spraying and heated drying.

UK Mainland Delivery, Ductwork & Installation Included

The price includes delivery to UK mainland sites, extraction ductwork and mechanical installation, subject to suitable site access and installation conditions.

With an internal working area of 6m wide x 10m long x 4m high, this spray room provides a substantial working space for larger products while allowing room for preparation, spraying and handling within the enclosed environment.

The room is constructed using insulated steel panels, providing a robust enclosure and helping to improve heat retention during heated operation. The insulated construction also provides a clean, controlled working environment suitable for demanding commercial finishing applications.

Gas-Fired Heating & Control System

The spray room incorporates an integrated gas-fired heating system designed to provide controlled heated air throughout the working area.

The control system incorporates dedicated spray and bake cycle functions, allowing the operator to select the appropriate operating cycle for the application. The bake cycle allows the room to be heated for accelerated drying following the spraying process, where permitted by the coating manufacturer’s requirements.

The heating system works alongside the extraction and air circulation arrangement to provide controlled environmental conditions during spraying and drying.

Rear Extraction System

Extraction is positioned at the rear of the spray room, providing a dedicated airflow path through the working area towards the extraction system.

The extraction chest is fitted with two 710mm belt-driven axial fans, each rated at 4.0kW and 23,115m³/hr, providing a combined extraction capacity of 46,230m³/hr.

The extraction chest incorporates Andreae AF923 High Efficiency Extract Filters, providing effective filtration of overspray before the extracted air passes into the ductwork system.

Fresh air enters through the roof-mounted BS290 blue and white roll filter, helping provide filtered air into the spray room during operation.

Large Insulated Roller Shutter Door

A large 5,000mm wide x 4,000mm high insulated roller shutter door is positioned at the front of the spray room, providing substantial access for loading and unloading larger components, assemblies, vehicles and other equipment.

The roller shutter features an insulated white finish to both sides, matching the white internal and external finish of the spray room for a clean and consistent appearance.

Personnel Access & Lighting

The spray room includes two personnel doors positioned on opposite sides and at opposite ends, providing convenient pedestrian access around the working area without requiring the main roller shutter to be opened.

Internal lighting is provided throughout the spray room to give operators clear visibility during preparation, spraying, drying and inspection.

Key Specification

  • Internal size: 6m Wide x 10m Long x 4m High
  • Application: Commercial and industrial spraying and heated drying
  • Construction: Insulated steel panel construction
  • Finish: White Exterior / White Interior
  • Heating: Integrated gas-fired heating system
  • Controls: Spray and bake cycle functions (Ambient up to 25°C spray mode & up to 60°C bake mode)
  • Main access: Insulated roller shutter door
  • Roller shutter: 5,000mm W x 4,000mm H
  • Roller shutter finish: Insulated white, both sides
  • Extraction: 2 x 710mm / 4.0kW belt-driven axial fans
  • Fan rating: 23,115m³/hr per fan
  • Total extraction: 46,230m³/hr
  • Extraction chest: Rear-mounted – 6000mm side
  • Extraction filtration: Andreae AF923 High Efficiency Extract Filter
  • Air input filtration: BS290 blue & white roll filter
  • Lighting: Internal lighting throughout
  • Personnel access: 2 personnel doors
  • Ductwork: Extraction ductwork included for a standard installation serving a building with a roof height of up to 6m
  • Delivery: UK mainland delivery included
  • Installation: Mechanical installation included on UK mainland sites

Designed for Large Commercial Applications

This heated spray room is suitable for businesses requiring a large controlled environment for professional spraying and accelerated heated drying. The combination of insulated construction, gas-fired heating, spray and bake cycle controls, high-capacity extraction and filtered air input provides a practical system for demanding commercial finishing applications.

APEX heated spray rooms can be configured around the customer’s application, site requirements and production process, with heating, extraction, access arrangements, lighting, ductwork and other equipment specified as part of the overall system.

For a bespoke quotation, technical specification or advice on configuring a heated spray room, contact the APEX team.

Please note: UK mainland delivery and installation are included in the advertised price based on a suitable, smooth and level installation site with appropriate access. The price includes extraction ducting for a standard installation with a building roof height of up to 6m. Site-specific requirements, additional ducting, building penetrations, lifting equipment, electrical mains connections and other works outside the stated installation scope may incur additional charges.